Optimization of Determination Conditions of Sulfur Dioxide Residue in Chilli Products by Automatic Potentiometric Titration
-
Graphical Abstract
-
Abstract
A method using automatic distillation apparatus coupled with automatic potentiometric titration was established to determine SO2 residue in chili products. The optimal conditions were determined by orthogonal test L16(45),and the results were as follows:The distillation time 5 min,the volume of distilled water 200 mL,the volume of received solution 40 mL,the stirring speed 8 r/min,the potential change rate 50 mV/min. On this condition,the relative standard deviations were between 0.69%~0.95%,the standard addition recoveries were between 98.3%~99.6%. This method is simple,rapid and accurate. It’s suitable for the automated testing of large quantities of sample. The results can provide reference for study SO2 residue in chili products and other food.
-
-